FX-2000owner’s m anualWHEN ACCURACY IS THE POINT.®TM

Seite 2

TO CHECK STORED READINGSThis feature allows you to view the total number of all accumulated readings, the average of those readings, and thehighest st

Seite 3 - TABLE OF CONTENTS

9Range of Moisture ContentThe FX-2000 is designed to test moisture in hay over a rangeof 6%-40%. Readings over 30% should be used only as aqualitative

Seite 4 - DELMHORST FX-2000

10CuringBefore proper curing has taken place, wide variations inmoisture content should be expected in both recently baledhay and hay in the windrow.

Seite 5 - CHECK CALIBRATION

Occasional higher readings may occur if, in addition to theeffect of the increased conductivity due to the stabilizer, thebales tested also show an in

Seite 6 - CHANGE THE SET-POINT

To install the #1986 bale sensor:Installation on a conventional small square baler:hLocate a spot on either side of the bale chamber, approxi-mately h

Seite 7 - Testing Baled Hay

13Installation on an Inline orCenter Line small square baler:hFollow instructions for installation as above.If placing the #1986 in the center channel

Seite 8 - Testing in the Windrow

VInstall sensor hereInstallation on a New Hollandor Case RBX Round Baler:hLocate a spot on either side of the bale chamber. hYour baler may contain a

Seite 9 - ! and take a reading

USING THE METER IN THECONTINUOUS MODEhChange the set-point to the desired value as described onpage 3. This must be done prior to turning the meter on

Seite 10 - FACTORS AFFECTING YOUR

We recommend that you spot check the windrow and freshlymade bales to give additional information with regard tothese differences and to help establis

Seite 11 - Hay Temperature

UNDER NO CIRCUMSTANCES SHALL DELMHORST BELIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL,OR CONSEQUENTIAL DAMAGES OF ANY TYPE WHAT-SOEVER, INCLUDING, BUT

Seite 13

51 Indian Lane EastTowaco, NJ 07082(877)[email protected]©2000, Delmhorst Instrument Co.510INS-0009 REV. 02/14 W

Seite 14

TABLE OF CONTENTS2 FX-2000 Features3 Before You Begin3 Using the Meter In The Portable Mode3 Check Calibration4 Change the Set-Point5 To Operate The B

Seite 15

%FX-2000 FEATURESh6% to 40% moisture range (starting with serial number19569) Dual mode - portable or continuous (on-the-gomonitoring)hDigital readout

Seite 16 - Installation on a New Holland

BEFORE YOU BEGINKey Functions! Read Key - Reads the percent moisture contentvalue %MC when the meter is in the portablemode. Turns the meter on in the

Seite 17 - USING THE METER IN THE

If you check the calibration and the display does not read“12,” it is likely an indication of a low battery. If thisoccurs, replace the battery with a

Seite 18 - WARRANTY

5TO OPERATE THE BACKLIGHThPress and release the calibration check key @. Within onesecond, press and hold the set-point increase key$.hHold the set-po

Seite 19 - SERVICE FOR YOUR METER

NoteshThe bale prod is electrically insulated, except at the metalpoints near the tip. The moisture content measured repre-sents the hay in contact wi

Seite 20

NoteshWhenever pressure is being applied on the electrode, be surethat the points of the electrode are touching nothing but thehay.hRepeat the steps a