FX-2000owner’s m anualWHEN ACCURACY IS THE POINT.®TM
TO CHECK STORED READINGSThis feature allows you to view the total number of all accumulated readings, the average of those readings, and thehighest st
9Range of Moisture ContentThe FX-2000 is designed to test moisture in hay over a rangeof 6%-40%. Readings over 30% should be used only as aqualitative
10CuringBefore proper curing has taken place, wide variations inmoisture content should be expected in both recently baledhay and hay in the windrow.
Occasional higher readings may occur if, in addition to theeffect of the increased conductivity due to the stabilizer, thebales tested also show an in
To install the #1986 bale sensor:Installation on a conventional small square baler:hLocate a spot on either side of the bale chamber, approxi-mately h
13Installation on an Inline orCenter Line small square baler:hFollow instructions for installation as above.If placing the #1986 in the center channel
VInstall sensor hereInstallation on a New Hollandor Case RBX Round Baler:hLocate a spot on either side of the bale chamber. hYour baler may contain a
USING THE METER IN THECONTINUOUS MODEhChange the set-point to the desired value as described onpage 3. This must be done prior to turning the meter on
We recommend that you spot check the windrow and freshlymade bales to give additional information with regard tothese differences and to help establis
UNDER NO CIRCUMSTANCES SHALL DELMHORST BELIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL,OR CONSEQUENTIAL DAMAGES OF ANY TYPE WHAT-SOEVER, INCLUDING, BUT
51 Indian Lane EastTowaco, NJ 07082(877)[email protected]©2000, Delmhorst Instrument Co.510INS-0009 REV. 02/14 W
TABLE OF CONTENTS2 FX-2000 Features3 Before You Begin3 Using the Meter In The Portable Mode3 Check Calibration4 Change the Set-Point5 To Operate The B
%FX-2000 FEATURESh6% to 40% moisture range (starting with serial number19569) Dual mode - portable or continuous (on-the-gomonitoring)hDigital readout
BEFORE YOU BEGINKey Functions! Read Key - Reads the percent moisture contentvalue %MC when the meter is in the portablemode. Turns the meter on in the
If you check the calibration and the display does not read“12,” it is likely an indication of a low battery. If thisoccurs, replace the battery with a
5TO OPERATE THE BACKLIGHThPress and release the calibration check key @. Within onesecond, press and hold the set-point increase key$.hHold the set-po
NoteshThe bale prod is electrically insulated, except at the metalpoints near the tip. The moisture content measured repre-sents the hay in contact wi
NoteshWhenever pressure is being applied on the electrode, be surethat the points of the electrode are touching nothing but thehay.hRepeat the steps a